Test with a multimeter
7-segment display
Now: Segment a: red on pin 7
Pin 1: e (e) Pin 2: d (d) Pin 3: Common cathode (COM) Pin 4: c (c) Pin 5: dp (dot) (dp) Pin 6: b (b) Pin 7: a (a) Pin 8: Common cathode (COM) Pin 9: f (f) Pin 10: g (g)
Red probe Not connectedBlack probe Not connected
LED litHold the probe and drag it to the tip of a leg. Tapping works too: first pick the probe, then the leg.
· beep
Set the range to diode test.
Measurement taken while pressed is saved. You can go to the next step.
Measure step by step
This guide uses a common-cathode 7-segment display (5161AS): the red probe is on the segment pin, the black probe on the common cathode (pin 3). With a common-anode display you reverse the probes; if you do not know the type, try the diode range first. The matching segment glows faintly while you measure.
- 1Segment a: red leg 7
- 2Segment b: red leg 6
- 3Segment c: red leg 4
- 4Segment d: red leg 2
- 5Segment e: red leg 1
- 6Segment f: red leg 9
- 7Segment g: red leg 10
- 8Segment dp: red leg 5
- 9Common cathode: legs 3 and 8
- 10Reverse direction: red on the common cathode